Rigidply Rafters Inc. Glu-Lam Posts
 |
Featuring: Southern Yellow Pine treated with CCA to a .60 pcf retention for Commercial, Residential, and Agricultural use. Reference Standards AWPA; C15, C16 and C28.
DISCOVER THE LABOR
SAVING ADVANTAGES:
-
Stronger - unequaled design values
-
Straighter - up to 60' long in a variety of sizes and configurations
-
Still CCA - more consistent and complete below ground .60 pcf CCA treatment.
-
Lighter - kiln dried after treating
-
Mininizes cracking, splitting and checking
-
Untreated tops, Standard
-
Structural Glu-Laminated Fingerjoints and Laminations - no nails, no construction adhesive, no butt-joints!
-
The most economical true Glu-Lam Post in the marketplace
-
Rigidply Rafters, Inc. - 50 years of unequaled manufacturing, people, and service.
-
Backed by an industry-leading 50 year warranty. Contact your Rigidply distributor to obtain a copy and discuss your project.
|
 |
STANDARD STOCK SIZES
3 ply 2 x 6, 5 1/4" x 4 1/16"
Standard lengths: 8' - 36'
3 ply 2 x 8, 7" x 4 1/16"
Standard lengths: 10' - 36'
4 ply 2 x 8, 7" x 5 3/8"
Standard lengths: 12' - 36'
|
 |
6'0" minimum standard treatment. Other sizes and lengths of treatment available upon request. Available in lengths to 60'0".

RIGIDPLY RAFTERS, Inc "GLU-LAM COLUMN" SPECIFICATIONS
All columns shall be Rigidply Rafters, Inc. Glu-Lam Columns manufactured of #1 southern yellow pine treated with CCA to a 0.6 pet retention and #2 untreated southern yellow pine. The treated portion shall be designed to extend at least one foot above the ground line. The adhesives 'shall be for
wet-use conforming to "ASTM D 2559". The laminations shall be surfaced, glued, and then clamped. The clamp-up shall be maintained at room temperature, at a minimum pressure of 100 PSI, for at least 10 hours, The Columns shall be surfaced, after curing, on the narrow faces of the laminations.
Each production lot shall be qualified by the following tests as described in AITC 200-92:
AITC Test T107 Shear
AITC Test T110 Cyclic Delamination
AITC Test T119 End Joint Tension
GLU-LAM POST ALLOWABLE DESIGN VALUES & SECTION PROPERTY
3 PLY 2 x 6:
Actual Size = 5.25" x 4.0625" .....................Fb y-y = 2050
psi
Area = 21.328 sq.
in......................................Fc = 2150 psi
Sy = 18.66 in.3................................................Ey-y
= 1700000 psi
Iy
= 48.99 in.4
3 PLY 2 x 8:
Actual Size = 7.0" x 4.0625" .......................Fb y-y
= 1900 psi
Area = 28.438 sq.
in......................................Fc = 2150 psi
Sy = 33.18 in.3................................................Ey-y
= 1700000 psi
Iy
= 116.12 in.4
4 PLY 2 x 6:
Actual Size = 5.25" x 5.375" .......................Fb y-y
= 2350 psi
Area = 28.219 sq.
in......................................Fc = 2150 psi
Sy = 24.691 in.3..............................................Ey-y
= 1700000 psi
Iy
= 64.815 in.4
4 PLY 2 x 8:
Actual Size = 7.0" x 5.375" .........................Fb y-y
= 2350 psi
Area = 37.625 sq.
in......................................Fc = 2150 psi
Sy = 43.90 in.3................................................Ey-y
= 1700000 psi
Iy
= 153.64 in.4
To view a copy of specifications for the Rigidply Rafters, Inc. Posts, click on the link below:
Post Specifications (pdf)
To view and print the Post Specifications, you will be Adobe Acrobat Reader. If you do not
have Adobe Acrobat Reader, click on Get Adobe Reader, to download and install
the latest version. It's free!