Rigidply Rafters Inc. Glu-Lam Posts

Featuring: Southern Yellow Pine treated with CCA to a .60 pcf retention for Commercial, Residential, and Agricultural use. Reference Standards AWPA; C15, C16 and C28.

DISCOVER THE LABOR
SAVING ADVANTAGES:

  • Stronger - unequaled design values
  • Straighter - up to 60' long in a variety of sizes and configurations
  • Still CCA - more consistent and complete below ground .60 pcf CCA treatment.
  • Lighter - kiln dried after treating
  • Mininizes cracking, splitting and checking
  • Untreated tops, Standard
  • Structural Glu-Laminated Fingerjoints and Laminations - no nails, no construction adhesive, no butt-joints!
  • The most economical true Glu-Lam Post in the marketplace
  • Rigidply Rafters, Inc. - 50 years of unequaled manufacturing, people, and service.
  • Backed by an industry-leading 50 year warranty. Contact your Rigidply distributor to obtain a copy and discuss your project.

STANDARD STOCK SIZES

3 ply 2 x 6, 5 1/4" x 4 1/16"
Standard lengths: 8' - 36'

3 ply 2 x 8, 7" x 4 1/16"
Standard lengths: 10' - 36'

4 ply 2 x 8, 7" x 5 3/8"
Standard lengths: 12' - 36'

6'0" minimum standard treatment. Other sizes and lengths of treatment available upon request. Available in lengths to 60'0".

RIGIDPLY RAFTERS, Inc "GLU-LAM COLUMN" SPECIFICATIONS

All columns shall be Rigidply Rafters, Inc. Glu-Lam Columns manufactured of #1 southern yellow pine treated with CCA to a 0.6 pet retention and #2 untreated southern yellow pine. The treated portion shall be designed to extend at least one foot above the ground line. The adhesives 'shall be for wet-use conforming to "ASTM D 2559". The laminations shall be surfaced, glued, and then clamped. The clamp-up shall be maintained at room temperature, at a minimum pressure of 100 PSI, for at least 10 hours, The Columns shall be surfaced, after curing, on the nar­row faces of the laminations.

Each production lot shall be qualified by the following tests as described in AITC 200-92:
AITC Test T107 Shear
AITC Test T110 Cyclic Delamination
AITC Test T119 End Joint Tension

 

 

 

 

GLU-LAM POST ALLOWABLE DESIGN VALUES & SECTION PROPERTY

  3 PLY 2 x 6:
       Actual Size = 5.25" x 4.0625" .....................Fb y-y = 2050 psi
       Area = 21.328 sq. in......................................Fc = 2150 psi

       Sy = 18.66 in.3................................................Ey-y = 1700000 psi

       Iy = 48.99 in.4
   3 PLY 2 x 8:
       Actual Size = 7.0" x 4.0625" .......................Fb y-y = 1900 psi
       Area = 28.438 sq. in......................................Fc = 2150 psi

       Sy = 33.18 in.3................................................Ey-y = 1700000 psi

       Iy = 116.12 in.4
   4 PLY 2 x 6:

       Actual Size = 5.25" x 5.375" .......................Fb y-y = 2350 psi
       Area = 28.219 sq. in......................................Fc = 2150 psi

       Sy = 24.691 in.3..............................................Ey-y = 1700000 psi

       Iy = 64.815 in.4
  4 PLY 2 x 8:

       Actual Size = 7.0" x 5.375" .........................Fb y-y = 2350 psi
       Area = 37.625 sq. in......................................Fc = 2150 psi

       Sy = 43.90 in.3................................................Ey-y = 1700000 psi

       Iy = 153.64 in.4